oo
Louise E Marks, MS, OTR
Registered Occupational Therapist
BCIA Certified in biofeedback, neurofeedback, pelvic muscle dysfunction biofeedback
Boulder NeuroTraining Center LLC
Screen of the Week 

 | Products | Workshops/ Consultation | Supervision | Home


Screen of the Week 

As I explore Infiniti BioGraph version 2.0, I often modify existing screens or create totally new ones to satisfy my biofeedback display preferences. I am offering you my favorites through the screen of the week program. Purchase through PayPal and the screen will be sent via e-mail. My thanks goes to Debora Elliott of Interactive Brain Analysis who helps me with development and testing of these screens. 

The following scripts and/or screens are for sale only to health care providers who are qualified by specialized training and their profession to use biofeedback modalities. Additionally, health care providers are expected to use these scripts and screens only within their professional scope of practice 

Louise Marks
Boulder NeuroTraining Center, LLC
2300 Broadway
Boulder, CO
303.447.8443
 


Download screens into the designated channel set folder within the SCREENS subdirectory of your Infiniti BioGraph Software, for example, PI 5 Ch Gen Physio Feedback.

Download scripts into the SCRIPTS subdirectory of your Infiniti BioGraph Software.

Temperature Screen
(Week 11/1/04)
Two screens: auditory and visual feedback with SC monitoring
Hardware and software requirements: 
     Infiniti BioGraph version 2.0 software,
     SC-Flex/Pro and temp sensor
     Infiniti BioGraph, ProComp+, ProComp2, or FlexComp Encoder
 
Screen Name
Channel Set
Hardware
Price 
PI BNC Temp Wheel
SC
PI 5 Ch Gen Physio Feedback.chs
BioGraph
Infiniti
$20.00
P+ BNC Temp Wheel SC
 P+ 5 Ch Multi Modality.chs
ProComp+
$20.00
P2 BNC Temp Wheel SC
P2 BNC SC Temp.chs
Note: This channel set will be sent to you. Download into channel subdirectory
ProComp2
$20.00
FI BNC Temp Wheel SC
F Inf 5 Ch Multi modality.chs
FlexComp
$20.00
A temperature screen with skin conduction monitoring. Auditory feedback is given only when the signal changes. When you purchase this screen you will receive two identical screens, one with proportional feedback (the tone goes up with temperture increases) and one with inverse proportional feedback (tone decreased with hand warming). Which screen you use is a matter of client and therapist preference Be sure to make the scale small around the temperature reading to give detail to the signal. If you animation is not moving or there is no feedback, check to see if your signal is out of range. Change the range by right clicking on the animation and then change the range values at the top of the screen. 

 

Skin Conduction Screen 
(Week 10/25/04)
Auditory and Visual Feedback with Temperature Monitoring
Hardware and software requirements: 
     Infiniti BioGraph version 2.0 software,
     SC-Flex/Pro and temp sensor
     Infiniti BioGraph, ProComp+, ProComp2, or FlexComp Encoder
 
Screen Name
Channel Set
Hardware
Price 
PI BNC SC Circle Temp
PI 5 Ch Gen Physio Feedback.chs
BioGraph
Infiniti
$20.00
P+ BNC SC Circle Temp
 P+ 5 Ch Multi Modality.chs
ProComp+
$20.00
P2 BNC SC Circle Temp
P2 BNC SC Temp.chs
Note: This channel set will be sent to you. Download into channel subdirectory
ProComp2
$20.00
FI BNC SC Circle Temp
F Inf 5 Ch Multi modality.chs
FlexComp
$20.00
This is a plain vanilla skin conduction screen which also monitors hand temperature. The audio feedback sounds only when the skin conduction signal changes offering useful training feedback without a continuous tone which can be distracting. To use the screen at it's best, be sure to make the scale appropriately narrow to give detail to the feedback. The circle animation changes color above and below a threshold.

Learn more about Louise E Marks, MS, OTR.
E-mail: Louise E. Marks, MS, OTR  biomarks@yahoo.com